Concepts— When using the RC-2II stand-alone configuration, the RC-2II transmitter is responsible for the two way communication link and quick-lock function for the robotic system. It is also important to note that communication can only happen when the RC-2II unit and the total station are pointed at each other.
Total Station Setup— (note: many of the settings below are defaulted correctly)
1. From the main total station menu:
• Select the Para Menu [F6]
• Select the Communication Menu [F2]
• Select Serial Port RS232C/RC [F1]
• Select
∗ Channel [1]
∗ RC [S]
∗ Retry [Std]
∗ Delimit [ETX]
∗ REC-A/B [B]
∗ NEZ-REC [Std]
∗ B.Rate [4800]
∗ Parity [None]
∗ Stop Bit [1]
• Press SET [F1] then YES [F5]
• Press [ESC] back to the main total station
menu.
2. From the Main Total Station Menu:
• Press Prog [F1] then MORE [F6]
• Press EXT.LINK [F3]
• Press 2. Setting [F2]
• Select 1. CABLE/RADIO MODEM/RC [F1]
• At the Setting menu, Select 3. PARAMETER (RC) [F3].
• Set Terminate to ETX. Press SET [F1]
• Set Retry to Standard. Press SET [F1]
• Set REC TYPE to REC-B. Press SET [F1]
• Press [ESC]
• Select 1. Execute [F1]
RC-2II
left. The other switches should be set the to left as well.
Recon Setup
1. Run Survey Pro and Open a job for work.
2. Go to [Job] - [Settings]
3. Press [Create New Instrument]
4. Create an Instrument Profile with the following settings.
• Name: Robot with RC2 Only
• Set the Brand to
• Set the Model to
• Ignore the Serial port and baud rate settings for now.
5. Press [Instrument Settings]
7. Track Light: Auto
8. Check the Remote Control option.
13.Press the {Track} index tab at the bottom of the display.
• GTS 820/GPT 8000/8200 should be set to
16. Set the Sensitivity to reflect the average distance that you will be shooting.
18. Press the {Correction} index tab at the bottom of the display.
19. Verify that all the correction values are set to: 0
20. Press the [green check] button to return back to the Instrument Setup Page.
21. Press the [Defaults] button to default the computed Baud Rate and Parity values.
Verify that the Baud Rate is set to 4800 and the Parity to None.
22. Press the [Send to Instrument] button. Survey Pro should return a “Happy”
sound.
23. Press the [green check] Button to exit out to the Instrument Profile page.
24. Press the [green check] again to exit back to the Main Survey Pro Menu.
25. Select [Survey] - [Remote Control].
26. Press the [Q-Lock] button to activate the Quick-Lock function.
27. Verify active Angles are updating on the display.
You are now connected to your total station and ready to begin your survey.