Tuesday, April 15, 2008
Concepts— When using the RC-2II stand-alone configuration, the RC-2II transmitter is responsible for the two way communication link and quick-lock function for the robotic system. It is also important to note that communication can only happen when the RC-2II unit and the total station are pointed at each other.
Total Station Setup— (note: many of the settings below are defaulted correctly)
1. From the main total station menu:
• Select the Para Menu [F6]
• Select the Communication Menu [F2]
• Select Serial Port RS232C/RC [F1]
• Select
∗
∗ Retry [Std]
∗ Delimit [ETX]
∗ REC-A/B [B]
∗ NEZ-REC [Std]
∗ TrkState [ON]
∗ B.Rate [4800]
∗ Data.L [8]
∗ Parity [None]
∗ Stop Bit [1]
2. From the Main Total Station Menu:
• Press Prog [F1] then MORE [F6]
• Press EXT.LINK [F3]
• Select 1. CABLE/RADIO MODEM/RC [F1]
• Using the Up/Down [F3/F4] arrow keys, select RC.
• Press SET [F1]
• At the Setting menu, Select 3. PARAMETER (RC) [F3].
• Using the Up/Down arrow keys, set Channel 1. Press SET [F1]
• Set Retry to Standard. Press SET [F1]
• Select 1. Execute [F1]
RC-2II
1. Open the battery chamber and remove the batteries. Locate the dip-switch block at the bottom of the battery chamber and verify that dip-switch 3 is to the
left. The other switches should be set the to left as well.
2. Put in fresh batteries if unsure about their age (typical battery life is 40 hrs).
Ranger Setup
2. Go to [Job] - [Settings]
3. Press [Create New Instrument]
4. Create an Instrument Profile with the following
• Name: Robot with RC2 Only
• Ignore the Serial port and baud rate settings for now.
5. Press [Instrument Settings]
6. Set the EDM Mode: to the desired resolution.
7. Track Light: Auto
8. Check the Remote Control option.
10.Set the desired Horizontal and Vertical Range.
11.Set Pattern to
13.Press the {Track} index tab at the top of the display.
14.Set the desired search delay value in the Start Searching After: Field. (3 is a typical value).
15. Set the Track Speed value.
• GTS 800/802/810/815 should be set to
• GTS 820/GPT 8000/8200 should be set to
16. Set the Sensitivity to reflect the average distance that
you will be shooting.
600ft),
17. Set the Turn Speed to
18. Press the {Correction} index tab at the bottom of the display.
19. Verify that all the correction values are set to: 0
20. Press the [green check] button to return back to the Instrument Setup Page.
21. Press the [Defaults] button to default the computed Baud Rate and Parity values.
Verify that the Baud Rate is set to 4800 and the Parity to None.
sound.
23. Press the [green check] Button to exit out to the Instrument Profile page.
24. Press the [green check] again to exit back to the Main Survey Pro Menu.
25. Select [Survey] - [Remote Control].
26. Press the [Q-Lock] button to activate the Quick-Lock function.
27. Verify active Angles are updating on the display.
You are now connected to your total station and ready to begin your survey.